A PCB relay footprint must match both the physical terminal pattern and the electrical function of every pin. Matching the case size or finding a relay with the same printed current rating is insufficient. Before approving a PCB relay replacement, compare the exact order code, drawing viewpoint, hole pattern, coil requirements, contact arrangement and board-level insulation design. Then validate a sample in the actual assembly. This guide uses Asiaon’s AS3F, AS115F and AS14FC PCB relay families to explain the review process without treating their similar applications as proof of interchangeability.
Product reference: AS3F / T73 product specifications and drawings.
Define what is allowed to change
Replacement projects fall into two different categories. A direct replacement must work within the existing board, enclosure and electrical design. A redesign may allow changes to the footprint, driver circuit or load path, but those changes bring additional validation work. Establish the category before comparing prices, because a low-cost component that requires a board revision is not a direct substitute.
Collect the original bill of materials, board revision, assembly drawing and complete relay marking. Identify any suffix for coil voltage, contact material, sealing or terminal arrangement. If records are missing, inspect an unused spare where possible and request the original documentation. A failed component can have burned markings or distorted pins, so measurements taken from it need careful interpretation.
Also record why a replacement is being considered. Obsolescence, delivery delay and field failure are different problems. If the original relay failed, determine whether the load, driver or assembly process contributed. Replacing the package without addressing that cause can repeat the same failure with a new part number.
Read the footprint drawing in the correct direction
Manufacturers may show a terminal layout from the bottom of the relay, from the component side of the board or from another stated reference. A mirrored interpretation can place the coil or load on the wrong terminals even when the mechanical hole pattern looks convincing. Write the drawing viewpoint on the comparison worksheet rather than relying on visual familiarity.
Choose a common reference point and compare the coordinates of every terminal. Include pin spacing, row spacing, terminal dimensions and any asymmetry that establishes orientation. Check the body outline and protruding features against nearby components. The board can accept the pins while still leaving inadequate clearance around a tall housing or an enclosure support.
Hole size also deserves explicit review. A terminal that can be forced into a hole is not necessarily compatible with the approved assembly process. The finished plated hole, terminal tolerances and soldering method must work together. Do not bend pins to make an unapproved alternative fit; that changes the intended mechanical arrangement and can stress the relay or board.

The AS115F product image illustrates a rectangular PCB relay with a different housing and terminal arrangement from the AS3F reference. Its dimensions and pin functions must be checked independently. A shared description such as PCB relay does not imply a shared footprint.
Build a pin-function comparison
For the underlying coil-and-contact principle, see the MIT relay workshop. The product-specific diagram governs the actual installation.
Make a row for each terminal on the original part and the proposed replacement. Identify the coil pair and every common, normally open and normally closed connection. For multiple poles, keep each contact set distinct. A different contact configuration can leave a board trace permanently connected or disconnected relative to the original design.
In a non-latching electromechanical relay, contact descriptions normally refer to the unenergized coil state. A latching relay requires its own state definition. Do not replace one with the other solely because the board pattern matches. The controller’s startup sequence and power-loss behavior could change even if a simple continuity test appears satisfactory.
A university relay demonstration linked below explains the separation between coil control and switched contacts. For a production board, that operating principle still needs to be translated into an exact pin map. The map should be reviewed before a powered test, not inferred from the sound of a relay clicking.
Use a replacement review table
| Review item | Evidence to request | Approval action |
|---|---|---|
| Mechanical fit | Body, terminal and hole drawings | Check the same reference and viewpoint |
| Pin functions | Coil and contact maps | Approve every terminal assignment |
| Coil drive | Supply, driver and suppression data | Validate startup and release |
| Load switching | Voltage, load type and duty | Use applicable ratings rather than case size |
| Board design | Current path and insulation review | Recheck affected tracks and spacing |
| Assembly | Soldering and cleaning instructions | Confirm the production process |
| Traceability | Order code and drawing revision | Retain approved sample results |
Basis: application review questions and the linked Asiaon product documentation; no additional product ratings are implied.
The table organizes the approval evidence. It is not a cross-reference declaring that any listed Asiaon relay replaces another manufacturer’s product. If the original application requires certified construction or a specified approval, confirm that requirement for the exact proposed part and the finished equipment.
Confirm the coil and driver can work together
The UNLV Relay Basics explains coil suppression, contact arrangements and why motor starting current differs from steady current. Apply the exact component data to the design.
The coil supply must match the ordered relay’s AC or DC type and nominal voltage. Review the permitted operating conditions, pickup requirements and behavior at the available supply extremes. For a DC coil, the driver must provide the necessary current without exceeding its own thermal or electrical limits. A replacement with the same nominal coil voltage can still place a different demand on the driver.
Check the driver circuit’s suppression arrangement. A diode, clamp or other protection device may be located on the board or incorporated into a particular relay option. Its polarity and voltage behavior must remain appropriate. Do not add a second suppressor casually or remove an existing one because a replacement appears to work during a short test.
Observe startup and shutdown behavior in the actual control circuit. Supply ramping, controller reset and shared-load voltage dips can produce conditions that a stable bench supply does not reproduce. If the application depends on release timing, verify it with the final suppression network and representative temperature. A nominally matching coil is only one part of that assessment.
Evaluate contact duty separately from package compatibility
Contact current is not the only switching requirement. Compare AC and DC voltage ratings, resistive and inductive duties, expected operating frequency and any minimum switching load. A board that switches a small signal has different concerns from one switching a motor or lamp. The large number printed on the case may describe only a particular rated test condition.
The AS3F product page identifies a 1Z contact arrangement and PCB terminals, while listing more than one resistive rating within the family information. The procurement decision must resolve the exact version and its applicable data rather than selecting the largest value in the table. Any claimed electrical life must be interpreted with its load and test conditions.
Do not calculate a supposed equivalent DC rating by preserving the product of voltage and current from an AC rating. Contact interruption depends on circuit behavior, not watts alone. Similarly, an unloaded continuity test cannot establish loaded switching life. Obtain appropriate application data and use a representative validation plan.

The AS14FC photograph provides a third PCB relay-family reference. Its transparent housing makes some internal parts visible, but visual inspection cannot establish contact material, insulation performance or an approval. Those details must come from traceable product documentation.
Review the board around the relay
The relay is only one part of the load current path. Board tracks, plated holes, connectors and solder joints must also support the intended operation. A replacement with a larger contact rating does not increase the capacity of an unchanged board. Look for evidence of local heating and investigate the complete connection path rather than treating the relay as the only possible source.
Creepage and clearance depend on the complete design and its applicable requirements. They cannot be selected from a universal gap value without considering the working voltage, insulation function and environment. A different terminal shape or body projection can change the board-level arrangement. Keep the appropriate electrical design review separate from a simple fit check.
Review assembly and cleaning compatibility as well. Follow the manufacturer’s permitted soldering process, orientation and cleaning instructions for the selected enclosure type. Do not assume that a dust-protected housing is washable or that a sealed package tolerates every solvent and process temperature. The finished board process must preserve the relay’s intended condition.
Validate samples in stages
Start with documentation and dimensional inspection before soldering. Confirm the delivered marking and terminal arrangement, then inspect seating and clearance on a representative board. Check that the relay is supported as intended and that the assembly process does not require forcing the component into place.
Follow with controlled electrical validation under an approved procedure. Confirm the unpowered contact state, intended operation and correct response when control power is removed. Measure the relevant coil behavior and assess the loaded circuit using suitable equipment. Where thermal performance or repeated switching matters, test under the actual duty and enclosure conditions rather than extrapolating from a few operations.
Record the sample identity, board revision, test conditions and acceptance criteria. A passing sample is evidence for the tested configuration, not a universal approval for every relay carrying a similar family name. Any later change to coil option, contact material or assembly process should trigger the appropriate review.
Send a complete replacement inquiry
Provide Asiaon with the original full order code, proposed product family, board drawing, pin map, coil supply and load description. State whether changing the board is permitted. Include environmental conditions, expected switching frequency, enclosure restrictions and required approvals. Ask for confirmation of the exact order code and any differences from the original device.
Keep the approved drawing and supplier response with the purchasing record. If several alternatives are accepted, document each separately. This avoids a future substitution based on a distributor’s short description or an image that omits the decisive suffix.
Frequently asked questions
Is the same case size enough for a direct replacement?
No. Terminal positions, pin functions, coil behavior, contact duty and assembly requirements must also match the approved application.
Can I turn a relay around to match a mirrored footprint?
Do not make that assumption. Resolve the drawing viewpoint and compare every pin function first. Physical rotation does not necessarily correct an electrical mismatch.
Does a higher current rating make a replacement better?
Not automatically. It may have different coil demands, contact behavior, minimum load requirements or dimensions. The complete application determines suitability.
Can a continuity test approve the replacement?
It can verify limited contact states under the test conditions. It cannot establish switching endurance, loaded temperature, insulation compliance or driver compatibility by itself.
Electrical servicing reference: 29 CFR 1910.333 electrical work practices, Cornell Legal Information Institute. Use the rules and approved procedures applicable to the installation; the relay is not a substitute for verified isolation.
Video: the operating principle behind the checks
RealPars explains the separation between relay control and switched load circuits. Use this background when reading the coil, contact and output diagrams discussed above; it does not specify wiring for an Asiaon model.
Watch What is a Relay System ? on YouTube
Continue planning the relay assembly
For a broader starting point, use our general-purpose relay selection guide. Review latching versus non-latching operation when defining the required state after control power changes, and our overview of general-purpose relay applications and advantages for the role of the control interface.