Interval Timer Relay: Define One-Shot Pulses and Retrigger Behavior

An interval timer relay turns its output on for a defined period after the specified starting event, then returns the output to its resting state. A single-shot function uses a control event to request that timed pulse. Before ordering, define whether the event is supply application, a rising or falling control transition, or another documented condition. Also define what happens when a second event arrives during timing. Retriggering can extend the active period, so two timers with the same dial setting can produce different machine behavior.

Use a sequence description alongside the timing diagram. “Five-second timer” identifies a duration but leaves the starting event, output state and response to repeated requests unresolved.

Separate interval, delayed pulse and repeating cycle functions

An immediate interval begins its active output period when the accepted starting event occurs. A delayed pulse waits first and then provides an output pulse. A repeating cycle alternates states repeatedly according to its configured operating conditions. These functions are not interchangeable, even if their enclosures and adjustment controls look similar.

IEC 61812-1 covers requirements and tests for time relays and includes definitions of relay types. Its public overview establishes that scope; it does not establish any AST18 product certification. Use the selected manufacturer’s timing diagram to determine the starting event and the conditions necessary before another cycle can begin.

Asiaon’s AST18-P pulse output timer is described as having separately set delay and operating times. That makes the distinction between waiting time and active output time especially important. The product name alone does not establish an immediate interval or a particular retrigger policy. Confirm the exact ordered function against its drawing before substitution.

Do not copy a function letter from another brand. Letters, front-panel symbols and terminal names can vary. Procurement should identify the required waveform and the complete product code, rather than treating a familiar letter as a universal specification.

Write the starting event in observable terms

Start with the process request. A sensor may provide a short pulse, a push button may remain held, and a controller may maintain its output until an acknowledgment arrives. Decide which transition the timer must recognize and what the system should do if that request remains active.

Keep supply and control separate in the description. A power-started interval can run whenever its supply is applied. A signal-started function may require a maintained supply and a separate control input. Replacing one with the other can create an unwanted pulse during startup or prevent a required pulse after the supply is already present.

Include the state at initial energization. Record whether the control input is initially inactive, already active, or changing while the supply rises. Some application problems appear only during that startup combination. A test that begins with an ideal inactive input can miss the installed sequence.

Define how the request returns to rest and how long it must remain there before another event is valid. A timer that requires a reset interval can ignore closely spaced requests even when its nominal active pulse is correct.

Choose the retrigger policy deliberately

A non-retriggerable single-shot function completes the accepted interval without restarting its timing for a repeated event during that interval. A retriggerable function restarts or extends timing according to its documented logic. For a concrete electronic example, the Texas Instruments CD74HC123 datasheet describes extending a monostable output pulse by retriggering. That IC example illustrates the principle; it is not a specification for an industrial timer relay.

Consider an illustrative command sequence with a nominal interval of five seconds and a second accepted trigger three seconds after the first. A non-retriggerable function would ordinarily finish the first interval at five seconds. A function that restarts a full interval at the second event would finish at eight seconds. These are conceptual examples, not AST18 specifications; the exact device diagram governs held inputs, release transitions and reset conditions.

The practical question is whether another request should be ignored, remembered, restart timing, or interrupt the output. Those are distinct behaviors. A timer that ignores extra requests does not necessarily queue them for later delivery.

For dosing, clamping or timed indications, extending the active output may have process consequences. Select the policy from the intended operation and risk assessment. A timer is a sequencing component; its presence alone does not establish a safety function or a maximum safe actuation duration.

AST18-M multifunction timer relay
AST18-M multifunction timer relay. Original Asiaon product photograph; consult the exact ordered version documentation.

Use a sequence acceptance table

This table turns the timing discussion into checks that can be observed during a controlled test. The control events and pulse-extension principle are discussed above; the selected timer diagram remains the application reference. The acceptance actions are application planning steps, not claims that every AST18 mode supports each behavior.

Review item Evidence to record Acceptance action
Start event Supply edge or documented control transition Confirm the first output change
Held request Input maintained beyond nominal pulse duration Compare behavior with the selected function diagram
Repeated request A valid event during the active period Verify ignore, restart or other documented policy
Rearming Input resting state and required reset interval Check the next event is accepted
Supply loss Interruption during waiting or active output Verify restart state and unintended-pulse prevention
Output path Contact state and downstream actuator response Measure at the point relevant to the process

Add the required output state to each row. A changeover contact can provide complementary paths, so the visible process action depends on which path is wired. Record whether the output description refers to the timer’s operated state, a normally open contact, a normally closed contact, or the final machine actuator.

Use a timing record with a common time reference. Input indication, internal timing indication, physical output contact and downstream actuator movement are different observations. The timer’s front LED may help diagnosis but should not be treated as direct proof that the final load received the intended pulse.

Match the control input before connecting the trigger

The sensor or controller must provide an input compatible with the ordered timer. Check the documented supply range, input type, terminal arrangement and control reference. Asiaon’s timer pages list control-signal options; that does not make every sensor output interchangeable.

For a transistor output, establish whether the arrangement is sourcing or sinking and whether its OFF-state leakage is acceptable. For a mechanical contact, establish whether the timer expects a clean transition and what input duration it recognizes. Do not add voltage to a control terminal based on a diagram from a different timer.

The AST18-M multifunction timer page identifies several power-controlled and externally controlled modes. Use it as a starting point for selecting the correct function, then verify the exact waveform and input version. A list of ten functions is not enough to approve an unspecified pulse sequence.

Inspect the installed control path too. A sensor can appear to stay active because of the process, wiring or supply behavior. Changing the time setting will not fix an input that never reaches the documented reset state.

AST18-N multifunction timer relay
AST18-N multifunction timer relay. Original Asiaon product photograph; consult the exact ordered version documentation.

Test pulse width at the output that matters

Choose a safe test arrangement before energization and follow applicable work practices. 29 CFR 1910.333 addresses electrical work practices. A deactivated timer input does not isolate the power circuit or establish that stored and separate energy sources are absent.

Begin with a single valid trigger and measure the output interval using equipment suitable for the circuit. Check both the leading and trailing transitions. If the actuator responds slowly, separate the timer output duration from the actuator’s travel or release time.

Then test a short request, a held request, a repeated request during timing, and a request immediately after the output ends. Apply the selected acceptance criteria instead of assuming all cases should produce the same waveform. A controlled supply interruption belongs in the sequence review as well, because restart behavior can create an extra pulse.

A pulse-width measurement must state where the probes or observation points were placed. A controller log may have limited scan resolution, and a mechanical output may introduce operating and release delays. Do not claim tighter timing performance than the measuring arrangement can resolve.

Where the process needs more than one interval, avoid accumulating assumptions. Check whether a second delay starts from the original input, the first output transition, or an independent feedback signal. The combined sequence can differ from the sum of two dial settings.

Approve the complete operating sequence

Use the AST18-N multifunction timer page when comparing external signal-controlled options. Its available modes must be checked individually; the family name does not establish that every desired trigger and retrigger combination is provided.

For procurement, supply a short written scenario and the required timing diagram. Include the supply, trigger source, active output duration, permitted waiting period, repeat-event policy, reset conditions and output load. State whether a new request during an active interval should be ignored or acted upon.

Output load selection remains separate from function selection. A timer that produces the correct pulse can still have an unsuitable contact rating for a motor, solenoid or other load. Account for the actual switching duty and use the approved interface where required.

Record the accepted settings and full product code after testing. Photographing the front setting helps maintenance, but it does not replace the function and wiring record. Keep the final diagram with the panel documentation so a replacement can be checked without recreating the sequence from memory.

Change one condition at a time during diagnosis. If the function, trigger wiring and duration are all changed together, an apparently successful trial may hide the original cause. Retest the relevant startup and repeated-request cases after the repair, then release the assembly only against the agreed behavior.

Frequently asked questions

Is an interval timer the same as an on-delay timer?

No. An interval function provides an active output period after its accepted starting event, whereas an on-delay function waits before operating its output. The exact supply and control conditions come from the ordered device’s timing diagram.

Will a second trigger always extend the output pulse?

No. That depends on the retrigger policy and accepted input conditions. A non-retriggerable single-shot function can ignore an additional event during timing. A retriggerable function can restart timing as documented. Do not assume that ignored requests are queued.

Can AST18-P be treated as an immediate single-shot replacement?

Its page describes a pulse output with separately adjustable delay and operating times. Confirm the selected function, start event and timing diagram before treating it as an immediate interval replacement. Also check input compatibility, reset behavior and the output load.

Video: measurement and circuit background

Ben Eater demonstrates a monostable 555 timer. The educational low-voltage circuit illustrates a one-shot pulse; it is not an AST18 wiring diagram and does not establish AST18 retrigger behavior.

Watch Monostable 555 timer – 8-bit computer clock – part 2 on YouTube

Related relay planning guides

For control component fundamentals, start with our general-purpose relay selection guide. Continue with on-delay and off-delay sequences, and timer restart after power failure.